Mecer 3000VA off-line UPS
- Category: UPS and Inverters
EXCLUDING VAT
R 3,315.00INCLUDING VAT
NB: Mobicred will only consider items priced under R35000
Quotes requested
All UPSs and Inverters are currently on back-order; please order now to get allocation from the next shipment.
Send us an email to sales@avico.pro or call us on 012 943 8111
Difference between Online UPS and Offline UPS
Quick Specs
- Capacity: 3000VA / 1800 W
- Connectivity, power output: 2 x SA 3-Pin Plug Sockets, 2 x IEC C13 Female Sockets
- Input: 220Vac-240Vac, 50/60Hz
- Output: 220Vac-240Vac, 50/60Hz
- Cold Start Function
- Power cables and cables that are used to connect to other devices are not included and can be bought separately.
Please visit link below for optional cables:
https://www.avico.pro/products/mecer-optional-cable?_pos=1&_sid=f82b186e5&_ss=r
https://www.avico.pro/products/copy-of-mecer-optional-cable-2-port?_pos=2&_sid=f82b186e5&_ss=r
Capacity
3000 VA / 1800 W
Input
Voltage
110/120 VAC or 220/230/240 VAC
Voltage Range
81-145 VAC / 162-290 VAC
Frequency Range
60-50 Hz (auto sensing)
Output
Output Voltage
110/120 VAC or 220/230/240 VAC
AC Voltage Regulation (Batt. Mode)
±10%
Frequency Range (Batt. Mode)
60 Hz or 50 Hz ±1 Hz
Transfer Time
Typical 2-6ms, 10ms max
Waveform (Batt. Mode)
Simulated Sine Wave
Battery
Battery Type & Number
12 V/9 AH x 4
Typical Recharge Time
4-6 hours recover to 90% capacity
Indicators
AC Mode
Green Lighting
Battery Mode
Yellow Flashing
Fault
Red lighting
Protection
Full Protection
Overload, discharge and over charge protection
Alarm
Battery Mode
Sounding every 10 seconds
Low Battery
Sounding every second
Overload
Sounding every 0.5 seconds
Battery Replacement Alarm
Sounding every 2 seconds
Fault
Continuously Sounding
Physical
Dimensions, D X W X H(mm)
495 x 150 x 250
Net Weight (kgs)
24.8
Operating Environment
Humidity
0-90 % RH @ 0- 40° (non-condensing)
Noise Level
Less than 40dB
Management
Optional USB/RS-232 Port
Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC
All UPSs and Inverters are currently on back-order; please order now to get allocation from the next shipment.
Send us an email to sales@avico.pro or call us on 012 943 8111
Difference between Online UPS and Offline UPS
Quick Specs
- Capacity: 3000VA / 1800 W
- Connectivity, power output: 2 x SA 3-Pin Plug Sockets, 2 x IEC C13 Female Sockets
- Input: 220Vac-240Vac, 50/60Hz
- Output: 220Vac-240Vac, 50/60Hz
- Cold Start Function
- Power cables and cables that are used to connect to other devices are not included and can be bought separately.
Please visit link below for optional cables:
https://www.avico.pro/products/mecer-optional-cable?_pos=1&_sid=f82b186e5&_ss=r
https://www.avico.pro/products/copy-of-mecer-optional-cable-2-port?_pos=2&_sid=f82b186e5&_ss=r
Capacity
3000 VA / 1800 W
Input
Voltage
110/120 VAC or 220/230/240 VAC
Voltage Range
81-145 VAC / 162-290 VAC
Frequency Range
60-50 Hz (auto sensing)
Output
Output Voltage
110/120 VAC or 220/230/240 VAC
AC Voltage Regulation (Batt. Mode)
±10%
Frequency Range (Batt. Mode)
60 Hz or 50 Hz ±1 Hz
Transfer Time
Typical 2-6ms, 10ms max
Waveform (Batt. Mode)
Simulated Sine Wave
Battery
Battery Type & Number
12 V/9 AH x 4
Typical Recharge Time
4-6 hours recover to 90% capacity
Indicators
AC Mode
Green Lighting
Battery Mode
Yellow Flashing
Fault
Red lighting
Protection
Full Protection
Overload, discharge and over charge protection
Alarm
Battery Mode
Sounding every 10 seconds
Low Battery
Sounding every second
Overload
Sounding every 0.5 seconds
Battery Replacement Alarm
Sounding every 2 seconds
Fault
Continuously Sounding
Physical
Dimensions, D X W X H(mm)
495 x 150 x 250
Net Weight (kgs)
24.8
Operating Environment
Humidity
0-90 % RH @ 0- 40° (non-condensing)
Noise Level
Less than 40dB
Management
Optional USB/RS-232 Port
Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC