Mecer 3000VA on-line UPS - Back-order
Rated 3.5/5 based on 11 customer reviews

Mecer 3000VA on-line UPS - Back-order

Availability: on request
R 5,600.00
EXCLUDING VAT
R 6,440.00
INCLUDING VAT


NB: Mobicred will only consider items priced under R35000

Quotes requested

All UPSs and Inverters are currently on back-order; please order now to get allocation from the next shipment.

Send us an email to sales@avico.pro or call us on 012 943 8111

Difference between Online UPS and Offline UPS

Quick Specs

  • Capacity: 3000 VA / 2400 W
  • Frequency Range: 40 Hz ~ 70 Hz
  • Battery Type: 12 V / 9 Ah
  • Pure Sinewave
  • Power cables and cables that are used to connect to other devices are not included and can be bought separately.

Please visit link below for optional cables:

https://www.avico.pro/products/mecer-optional-cable?_pos=1&_sid=f82b186e5&_ss=r

https://www.avico.pro/products/copy-of-mecer-optional-cable-2-port?_pos=2&_sid=f82b186e5&_ss=r

Phase
Single phase with ground

Capacity
3000 VA / 2400 W

Input
Voltage Range
Low Line Transfer
160 VAC/140 VAC/120 VAC/110 VAC ± 5% (Ambient Temp. <35°C) (based on load percentage 100% - 80% / 80% - 70% / 70-60% - 0)

Low Line Comeback
175 VAC/155 VAC/135 VAC/125 VAC ± 5% (Ambient Temp. <35°C) (based on load percentage 100% - 80% / 80% - 70% / 70-60% - 0)

High Line Transfer
300 VAC ± 5%

High Line Comeback
290 VAC ± 5%

Frequency Range
40 Hz ~ 70 Hz

Power Factor
≥ 0.99 @ nominal voltage

Output
Output Voltage
200/208/220/230/240 VAC

AC Voltage Regulation (Batt. Mode)
± 1%

Frequency Range (Synchronised Range)
47 ~ 53 Hz or 57 ~ 63 Hz

Frequency Range (Batt. Mode)
50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz

Current Crest Ratio
3:1

Harmonic Distortion
≤ 3 % THD (Linear Load), ≤ 6 % THD (non-linear load)

Transfer Time
AC Mode to Batt. Mode
Zero

Inverter to Bypass
4ms (Typical)

Waveform (Batt. Mode)
Pure Sinewave

Efficiency
AC Mode
90%

Battery Mode
88%

Battery
Battery Type
12 V / 9 Ah

Numbers
6

Typical Recharge Time
4 hours to recover to 90% capacity

Charging Current (max.)
1.0 A

Charging Voltage
82.1 VDC ± 1%

Indicators
LCD Panel
UPS status, Load level, Battery level, Input/output Voltage, Discharge timer and Fault Conditions

Alarm
Battery Mode
Sounding every 4 seconds

Low Battery
Sounding every second

Overload
Sounding twice every second

Fault
Continuously sounding

Physical
Dimension, D x W x H (mm)
630 x 483 x 88 [2U]

Net Weight (kgs)
29.3

Environment
Humidity
20-90 % RH @ 0-40°C (non-condensing)

Noise Level
Less than 50dB @ 1 Meter

Management
Smart RS-232/USB
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix and Mac

Optional SNMP
Power management from SNMP manager and web browser

All UPSs and Inverters are currently on back-order; please order now to get allocation from the next shipment.

Send us an email to sales@avico.pro or call us on 012 943 8111

Difference between Online UPS and Offline UPS

Quick Specs

  • Capacity: 3000 VA / 2400 W
  • Frequency Range: 40 Hz ~ 70 Hz
  • Battery Type: 12 V / 9 Ah
  • Pure Sinewave
  • Power cables and cables that are used to connect to other devices are not included and can be bought separately.

Please visit link below for optional cables:

https://www.avico.pro/products/mecer-optional-cable?_pos=1&_sid=f82b186e5&_ss=r

https://www.avico.pro/products/copy-of-mecer-optional-cable-2-port?_pos=2&_sid=f82b186e5&_ss=r

Phase
Single phase with ground

Capacity
3000 VA / 2400 W

Input
Voltage Range
Low Line Transfer
160 VAC/140 VAC/120 VAC/110 VAC ± 5% (Ambient Temp. <35°C) (based on load percentage 100% - 80% / 80% - 70% / 70-60% - 0)

Low Line Comeback
175 VAC/155 VAC/135 VAC/125 VAC ± 5% (Ambient Temp. <35°C) (based on load percentage 100% - 80% / 80% - 70% / 70-60% - 0)

High Line Transfer
300 VAC ± 5%

High Line Comeback
290 VAC ± 5%

Frequency Range
40 Hz ~ 70 Hz

Power Factor
≥ 0.99 @ nominal voltage

Output
Output Voltage
200/208/220/230/240 VAC

AC Voltage Regulation (Batt. Mode)
± 1%

Frequency Range (Synchronised Range)
47 ~ 53 Hz or 57 ~ 63 Hz

Frequency Range (Batt. Mode)
50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz

Current Crest Ratio
3:1

Harmonic Distortion
≤ 3 % THD (Linear Load), ≤ 6 % THD (non-linear load)

Transfer Time
AC Mode to Batt. Mode
Zero

Inverter to Bypass
4ms (Typical)

Waveform (Batt. Mode)
Pure Sinewave

Efficiency
AC Mode
90%

Battery Mode
88%

Battery
Battery Type
12 V / 9 Ah

Numbers
6

Typical Recharge Time
4 hours to recover to 90% capacity

Charging Current (max.)
1.0 A

Charging Voltage
82.1 VDC ± 1%

Indicators
LCD Panel
UPS status, Load level, Battery level, Input/output Voltage, Discharge timer and Fault Conditions

Alarm
Battery Mode
Sounding every 4 seconds

Low Battery
Sounding every second

Overload
Sounding twice every second

Fault
Continuously sounding

Physical
Dimension, D x W x H (mm)
630 x 483 x 88 [2U]

Net Weight (kgs)
29.3

Environment
Humidity
20-90 % RH @ 0-40°C (non-condensing)

Noise Level
Less than 50dB @ 1 Meter

Management
Smart RS-232/USB
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix and Mac

Optional SNMP
Power management from SNMP manager and web browser