• Simulated sinewave inverter

• Wide input voltage range

• 12VDC or 24VDC available

• Overload and short circuit protection

• LCD display for comprehensive information

• Optional solar charger

 

CAPACITY 2400VA/ 1440W
Voltage 230 VAC
Acceptable Voltage Range 90-280 VAC
Frequency 50 Hz/60 Hz (Auto sensing)
AC Voltage Regulation (Batt. Mode) ± 10%
Efficiency (Peak) 85%
Transfer Time 20 ms typical
Waveform (Batt. Mode) Simulated sine wave
Battery Voltage 24 VDC
Floating Charge Voltage 27.4 VDC ±2%
Low Battery Alarm Voltage 20.4Vdc ±2%
Shutdown Voltage 19.8Vdc ±2%
Overcharge Protection 30.0Vdc ±2%
Maximum Charge Current 10 A or 20 A (Selectable)
Maximum PV Array Open Circuit Voltage 60 VDC
Operating Voltage Range 30~32 VDC
Maxmum Solar Charge Current 50 A
Full Protection Overload, short circuit and polarity reserve protection
Dimension, D X W X H (mm) 300 x 360 x 88
Net Weight (kgs) 4.8
Humidity 0 to 90% Relative Humidity(Non-condensing)
Operating Temperature 0℃ to 40℃
Storage Temperature -15℃ to 50℃

All UPSs and Inverters are currently on back-order; please order now to get allocation from the next shipment.

Send us an email to sales@avico.pro or call us on 012 943 8111

• Simulated sinewave inverter

• Wide input voltage range

• 12VDC or 24VDC available

• Overload and short circuit protection

• LCD display for comprehensive information

• Optional solar charger

 

CAPACITY 2400VA/ 1440W
Voltage 230 VAC
Acceptable Voltage Range 90-280 VAC
Frequency 50 Hz/60 Hz (Auto sensing)
AC Voltage Regulation (Batt. Mode) ± 10%
Efficiency (Peak) 85%
Transfer Time 20 ms typical
Waveform (Batt. Mode) Simulated sine wave
Battery Voltage 24 VDC
Floating Charge Voltage 27.4 VDC ±2%
Low Battery Alarm Voltage 20.4Vdc ±2%
Shutdown Voltage 19.8Vdc ±2%
Overcharge Protection 30.0Vdc ±2%
Maximum Charge Current 10 A or 20 A (Selectable)
Maximum PV Array Open Circuit Voltage 60 VDC
Operating Voltage Range 30~32 VDC
Maxmum Solar Charge Current 50 A
Full Protection Overload, short circuit and polarity reserve protection
Dimension, D X W X H (mm) 300 x 360 x 88
Net Weight (kgs) 4.8
Humidity 0 to 90% Relative Humidity(Non-condensing)
Operating Temperature 0℃ to 40℃
Storage Temperature -15℃ to 50℃